TrueFill Guard • ACIDS • CAUSTICS • CORROSIVE CHEMICALS • LOW-DIELECTRIC LIQUIDS

Advanced protection Built for

Corrosive and Low-Dielectric liquids

TrueFill GUARD gives bulk liquid transport fleets reliable tank-level visibility and automatic shutdown protection across acids, caustics, and corrosive chemicals. Built for the harshest liquids you haul.

BOOK A FLEET ASSESSMENTCALCULATE YOUR ROI

APPLICATION FIT

ACIDS

CAUSTICS

CORROSIVE CHEMICALS

LOW-DIELECTRIC LIQUIDS

C-276
HASTELLOY WETTED MATERIALS

Hastelloy® C-276 coatings, specified for acidic and caustic service where accuracy and durability matter most.

BUILT FOR CORROSIVE SERVICE

1+ yrs
Proven Measurement Platform

Rugged, solid-state measurement for the hardest 
applications in bulk liquid transport.

MEASUREMENT BUILT FOR HARSH DUTY

ZERO
MOVING PARTS. ZERO RECALIBRATION.

No wetted electronics and no moving parts means nothing for aggressive product to wear.

Chemical-Duty Build

Titan Gauges are exceptional products. We’ve seen tremendous accuracy in every reading, and the service department is always top-notch. THEIR sales manager, Ryley Williamson, is consistently responsive and goes above and beyond to help in any way possible. 
Highly recommend. 

MARK VANBUSKIRK

GENERAL MANAGER, DBTC LLC

FEATURES 

Built for the harshest environments

Every Titan Solution delivers accurate, reliable, and durable tank level measurement, with add-on
features that scale with your business.

BASE SYSTEM

Liquid Level Measurement

specifically designed for acidic and CAUSTIC corrosive chemicals

  • Guided wave radar delivers unparalleled accuracy (±5 mm) every time
  • Titan’s Hastelloy® C-276 probe is built for acid and corrosive applications
  • No float to seize, no optics to foul
  • NO moving parts, no calibration, no routine maintenance
Outcome

Accurate volume you can trust on aggressive product, where dipping is dangerous and other sensors fail.

ADD ON

onboard pump shutdown

ELIMINATE SPILLS WITH FAIL-SAFE OVERFILL PREVENTION IN THE FIELD 

  • Multiple, configurable alarms to suit your workflow
  • Wire the FINCH display to the PTO for automated, fail-safe shutdown
  • The industry standard for spill prevention
  • Supports multiple compartments, including lead + pup configurations
OUTCOME

Titan’s fail-safe overfill prevention for on-board pumps is the gold standard in the industry. Click below to learn more about onboard pump control.

ADD ON

terminal overfill prevention

terminal overfill prevention and tank level measurement in one package

  • TrueFill GUARD Solution replaces the traditional optic overfill sensors and onboard monitors
  • Delivering fail-safe overfill prevention at the rack for over 15 years
  • Zero down time - never replace a failed overfill sensor again
  • Interoperable with industry standard sockets and rack monitors 
OUTCOME

Boost your fleet’s performance with real-time tank level visibility and overfill prevention all in one package. Click the links below for more information.

CONNECTED PLATFORM

TITAN INSTALL • TITAN PORTAL

Every TrueFill GUARD Solution ships connected.
Commission it from a phone, track assets from the office, and service in the field.
01
Commission and program from a phone or tablet. 
No cables, no laptop, no second trip.
02
Remote diagnostics and full device history in Titan Portal. Fewer service calls, faster answers.
03
Cloud strapping tables and volume mapping, always current and ready to deploy.
Included with TrueFill PRO, TrueFill CORE, and TrueFill GUARD solutions at no extra cost.
SEE HOW THEY WORK
THE TRUEFILL GUARD COMPONENTS

Your truefill guard system.

Click on each component to learn more.

C-276

CONTINUOUS VISIBILITY · NO MOVING PARTS
COMPARTMENT VISIBILITY

Precise volume in aggressive product. The GUARD probe is machined from solid Alloy C-276 (UNS N10276) bar, the nickel-molybdenum-chromium alloy specified for hydrochloric and sulphuric acid service. Solid alloy through the full section: no coating to breach, no plating to wear through, no substrate underneath. No moving parts and no wetted electronics. Once installed, Titan probes require zero routine maintenance.

WHY IT MATTERS
One number from empty to full, not trip points
Hastelloy C-276 coatings, specified for acidic and caustic service
±5 mm accuracy you can stand behind in a dispute
No moving parts, no recalibration, no routine service interval

TD100R TRANSMITTER

SEALED · CHEMICAL-DUTY

ROLE
Converts the probe signal into a verified volume while staying sealed against a corrosive operating environment.

WHY IT MATTERS
Verified data to FINCH III
Sealed, chemical-duty housing
Stable in vibration and temperature swings
Field-serviceable and proven over decades

FINCH III DISPLAY

ONBOARD MONITOR • UP TO 6 COMPARTMENTS

ROLE
The operator interface for the entire system. Displays live per-compartment levels and alarm status. One display monitors up to 6 compartments.

WHY IT MATTERS
Live per-compartment volume at a glance
Setpoints configured per product and compartment
Device history and configuration synced to Titan Portal
Device history synced to Titan Portal

JUNCTION BOX

CENTRALIZED WIRING • Sealed
COMPARTMENT VISIBILITY

ROLE
Ties every compartment’s signal into one clean, sealed connection point built for the road.

WHY IT MATTERS
Centralizes probe and transmitter wiring
Sealed against weather and washdown
Simplifies install and service
Built for the vibration of mobile use
THE TITAN STANDARD

When the margin for error is zero, titan delivers

Every Titan system is engineered to perform where reliability, safety, and operational confidence matter most. 
REQUEST A QUOTE
PROVEN PERFORMANCE

Measurement that reads the same in year ten as day one. No drift, no recalibration, no guessing.

CONNECTED TECHNOLOGY

Built to integrate with the systems you use today and scale with your operation as
it evolves.

ACCURACY THAT COUNTS

Continuous volume on every compartment, accurate enough to bill and reconcile without manual gauging. Keeping drivers safe and margin high.

PARTNERSHIP THAT LASTS

A North America-wide service network and direct engineering support, from the first install through the life of the system.

CLose